Ask a question about this product
MPRA 350 S medicine refrigerator closed door with DIN 58345 / 13277
• Capacity: 340 litres
• External dimensions (W x D x H): 600 x 700 x 1510 mm
• Internal dimensions (W x D x H): 480 x 500 x 1358 mm
• Executed in accordance with DIN 58345 / 13277
• Number of grids: 5
Read more
The Medifridge MPRA 350 S is a reliable medication refrigerator from the Medgree line. This small refrigerator model - with a temperature range of +2°C to +8°C - is often found at general practitioners, pharmacies, hospitals and laboratories.
The MPRA 350 S is equipped with a self-closing, solid door and with a volume of 340 liters, it is easy to place anywhere. The refrigerator is equipped with various alarm functions to ensure the safety of the products. For example, the refrigerator gives both an optical and an acoustic signal if the temperature exceeds the limits or the door of the refrigerator is open too long. The refrigerator will also give an alarm in the event of a power failure. Furthermore, this refrigerator is equipped with an integrated temperature data logger. These functions are adjustable via a user-friendly interactive display. The required data can be read at all times on this display.
Internally, the MPRA 350 S is acquired from white plastic material. There is a fan at the top of the refrigerator. This ensures effective air circulation so that the temperature remains the same throughout the cabinet. The rear wall protection ensures that no products can be placed against the evaporator. There is also LED lighting at the top of the refrigerator.
As standard, the MPRA 350 S is equipped with 5 wire grids and a glycerol bottle. Optionally, an extra wire grid can be ordered (accessory).
DIN 58345 / 13277 standard for medicine refrigerators
DIN stands for "Deutsches Institut für Normung" (German National Standards Body). The DIN issues standards that are valid in Germany. DIN 58345 / 13277 is the standard for a medicine refrigerator, which is used to store medicines at a temperature of +5°C. The medicine refrigerators must meet the following requirements:
- A stable operating temperature of between +2°C and +8°C.
- An ambient temperature to guarantee this is between +10°C and +35°C.
- A safety thermostat up to +2°C (so the refrigerator can never get colder than +2°C).
- Power failure detector that can give a signal for at least 12 hours with its own battery.
- Potential-free contact to be able to forward messages to a system.
- Optical and acoustic signals for temperature alarms.
- Support platforms that can have a load of 100 kg/m².
- Maximum sound level 60 dB(A).
- A door that can be closed with a lock.
Contents | 340 Liter |
Outer dimensions (wxdxh) | 600 x 700 x 1510 mm |
Inner dimensions (wxdxh) | 480 x 500 x 1358 mm |
Complies with DIN 58345 / DIN 13277 standard | Yes |
Air circulation | Forced circulation |
Cooling system | Compressor cooling |
Defrost system | Automatically |
Temperature range | 2 °C to 8 °C |
Default temp. institution | 5 °C |
Housing material | Steel / White |
Interior material | Plastic / White |
Door material | Steel |
Control type | Electronic |
Control panel type | Touch key |
Interactive display | Yes, incl.keyboard lock |
Real time clock | Yes |
Readout type | Digital |
Open door alarm | Yes |
Fault signal | Yes |
Potentialfree contact | Yes |
Indoor lighting | Yes |
Freeze protection | Yes |
Sensor throughput | Yes |
Evaporator protection | Yes |
Number of wire grids | 3 pieces |
Noise level | < 45 dB(A) |
Lock by key | Yes |
Door hinge | Right, interchangeable |
Temperature data logger | Yes |
Glycerol bottle | Yes |
Logger readout type | Via USB |
Calibration | 6 points |
Power failure detector | Yes |
Alarm battery | Yes |
Backup Battery | Yes |
Temp. power failure registration | Yes |
Net weight | 79 kg |
Adjustable feet | Yes |
Refrigerant | R600A |
Connection value | 230 Volt 50Hz |
Guarantee | 3 years |